Inverter Heater Air To Water Heat Pump
The temperature of traditional air energy can only reach about 60℃. The temperature test of the single-pole variable frequency high temperature hot water and hot air unit developed by Huameirun using refrigerant heat superposition technology can reach 95℃ (the operating environment is above 10 degrees).
Products Description
High temperature laminated air energy heat pump series
Technical advantages
The temperature of traditional air energy can only reach about 60℃. The temperature test of the single-pole variable frequency high temperature hot water and hot air unit developed by Huameirun using refrigerant heat superposition technology can reach 95℃ (the operating environment is above 10 degrees). The temperature of the unit developed by Huameirun is inverter heater air to water heat pump is widely used in electroplating, slaughtering, sauna, food processing and other related fields, and its energy consumption is lower than that of traditional electric heating. , natural gas savings of 50%-70%.
Product Parameter
High temperature overlying air energy parameter table
|
Model |
3P |
6P |
||||||||||
|
Project Category/Ambient Temperature |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
-20℃ |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
-20℃ |
|
Heating input power (KW) |
2.86 |
2.88 |
2.91 |
2.95 |
2.97 |
3.2 |
5.71 |
5.76 |
5.82 |
5.89 |
5.94 |
6.39 |
|
Heating capacity (KW) (65°C water outlet) |
6.77 |
6.73 |
6.68 |
6.69 |
6.68 |
6.656 |
13.58 |
13.47 |
13.386 |
13.37 |
13.36 |
13.35 |
|
Performance index COP (H) |
2.37 |
2.34 |
2.3 |
2.27 |
2.25 |
2.08 |
2.38 |
2.34 |
2.3 |
2.27 |
2.25 |
2.09 |
|
Physical dimension |
Subject to actual size |
Subject to actual size |
||||||||||
|
Model |
8P |
10P |
||||||||||
|
Project Category/Ambient Temperature |
10℃ |
0℃ |
-5℃ |
-10℃ |
15℃ |
-20℃ |
10℃ |
0℃ |
5℃ |
-10℃ |
-15℃ |
-20℃ |
|
Heating input power (KW) |
7.62 |
7.68 |
7.76 |
7.86 |
7.92 |
8.53 |
9.6 |
9.72 |
9.76 |
9.9 |
9.96 |
10.13 |
|
Heating capacity (KW) (65°C water outlet) |
18.05 |
17.97 |
17.84 |
17.8 |
17.78 |
17.7 |
23.32 |
22.8 |
22.64 |
22.57 |
22.31 |
21.27 |
|
Performance index COP (H) |
2.37 |
2.34 |
2.3 |
2.27 |
2.25 |
2.08 |
2.43 |
2.35 |
2.32 |
2.28 |
2.24 |
2.1 |
|
Physical dimension |
Subject to actual size |
Subject to actual size |
||||||||||
|
Model |
15P |
20P |
||||||||||
|
Project Category/Ambient Temperature |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
20℃ |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
-20℃ |
|
Heating input power (KW) |
14.4 |
14.58 |
14.64 |
14.85 |
14.94 |
15.19 |
19.2 |
19.44 |
19.52 |
19.8 |
19.92 |
20.26 |
|
Heating capacity (KW) (65°C water outlet) |
34.84 |
34.11 |
33.81 |
33.7 |
33.31 |
31.74 |
46.27 |
45.48 |
45.09 |
44.94 |
44.42 |
42.14 |
|
Performance index COP (H) |
2.42 |
2.34 |
2.31 |
2.27 |
2.23 |
2.09 |
2.41 |
2.34 |
2.31 |
2.27 |
2.23 |
2.08 |
|
Physical dimension |
Subject to actual size |
Subject to actual size |
||||||||||
|
Model |
25P |
30P |
||||||||||
|
Project Category/Ambient Temperature |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
-20℃ |
10℃ |
0℃ |
5℃ |
-10℃ |
-15℃ |
-20℃ |
|
Heating input power (KW) |
24 |
24.3 |
24.4 |
24.75 |
24.9 |
25.32 |
28.8 |
29.16 |
29.28 |
29.7 |
29.88 |
30.39 |
|
Heating capacity (KW) (65°C water outlet) |
57.9 |
56.6 |
56.12 |
55.93 |
55.5 |
52.91 |
69.69 |
66.77 |
66.46 |
66.23 |
66.03 |
63.5 |
|
Performance index COP (H) |
2.413 |
2.33 |
2.3 |
2.26 |
2.23 |
2.09 |
2.42 |
2.29 |
2.27 |
2.23 |
2.21 |
2.09 |
|
Physical dimension |
Subject to actual size |
Subject to actual size |
||||||||||
|
Model |
50P |
60P |
||||||||||
|
Project Category/Ambient Temperature |
10℃ |
0℃ |
-5℃ |
-10℃ |
15℃ |
-20℃ |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
-20℃ |
|
Heating input power (KW) |
48 |
48.6 |
48.8 |
49.5 |
49.8 |
50.65 |
57.6 |
58.32 |
58.56 |
59.4 |
59.76 |
60.78 |
|
Heating capacity (KW) (65°C water outlet) |
115.68 |
112.75 |
112.24 |
111.87 |
111.05 |
138.81 |
134.78 |
134.71 |
134.1 |
133.65 |
133.26 |
127.03 |
|
Performance index COP (H) |
2.41 |
2.32 |
2.3 |
2.26 |
2.23 |
2.08 |
2.41 |
2.31 |
2.29 |
2.25 |
2.23 |
2.09 |
|
Physical dimension |
Subject to actual size |
Subject to actual size |
||||||||||
|
Model |
100P |
|||||
|
Project Category/Ambient Temperature |
10℃ |
0℃ |
-5℃ |
-10℃ |
-15℃ |
-20℃ |
|
Heating input power (KW) |
95.3 |
96 |
97 |
98.3 |
99 |
106.6 |
|
Heating capacity (KW) (65°C water outlet) |
225.86 |
224.64 |
223.1 |
223.14 |
222.75 |
222.36 |
|
Performance index COP (H) |
2.37 |
2.34 |
2.3 |
2.27 |
2.25 |
2.086 |
|
Physical dimension |
Subject to actual size |
|||||
Our Service
• During the design process, the after-sales service department is responsible for putting forward specific technical requirements for the reliability of the product and the maintenance-free nature of the inverter heater air to water heat pump equipment based on the different requirements of users, striving to pursue low failure rates and minimal maintenance, convenient maintenance;
• Work side by side with users when implementing projects to jointly ensure project quality;
• Submit standardized and complete drawings and "maintenance instructions" to users, and provide users with necessary vulnerable spare parts;
• Carefully provide technical training on operation, use and maintenance before handing it over to the user for use;
• Establish after-sales service files and manage them with the help of electronic operating systems. During use, we strictly conduct regular return visits and inspections to customers, and provide timely and effective maintenance guidance and maintenance services.
Hot Tags: inverter heater air to water heat pump, China inverter heater air to water heat pump manufacturers, suppliers, factory, Inverter Heater Air To Water Heat Pump, coldchain technology services, High temperature laminated air energy heat pump, Fruit Tree Hibernation Temperature Control Unit, refrigerated storage unit, commercial hybrid water heater
Send Inquiry